Quick answer

Most bore pump problems come down to one of four things: no power reaching the pump, a fault in the pressure switch or controls, a leak that keeps the pump cycling, or a change in the bore itself, such as sand or a falling water level. You can safely check the breaker, look for leaks and note exactly what the pump is doing. Anything inside the pump, the pressure switch or the control box is a job for a licensed professional.

In this article

  1. Start with what the pump is actually doing
  2. The pump won’t start
  3. The pump runs but no water comes through
  4. Do you need to prime a bore pump?
  5. The pump keeps cycling on and off
  6. Sand, discoloured water or a smell
  7. When to call, and what to have ready
  8. FAQs

When the taps run dry or the troughs stop filling, the first question is usually whether it’s the pump or the bore. Often you can narrow it down in ten minutes without touching anything you shouldn’t. This guide walks through the common symptoms, what each one usually points to, and the point where it’s time to stop checking and call someone in.

Start With What the Pump Is Actually Doing

Before you change anything, stand near the pump and the outlets and note what’s happening. The symptom tells you far more than “it’s not working” does.

What you noticeWhat it often points toWhat you can safely check
Pump is silent, nothing happensNo power, a tripped breaker, or a control or pressure switch faultThe breaker or RCD for the pump at your switchboard
Pump runs but little or no waterWater level below the pump, a blockage, a damaged pipe or a worn pumpWhether every outlet is affected, and how long it’s been dry
Pump cycles on and off with taps closedA leak somewhere in the system, a pressure tank problem or a pressure switch faultTroughs, float valves, irrigation lines and taps for leaks
Pump runs and won’t switch offA big leak, a pressure switch fault or a pump that can’t build pressureTurn off outlets one at a time and note any change
Sand, cloudy or smelly waterA problem with the bore itself, often the screen or gravel packWhen it started and whether it’s getting worse

The Pump Won’t Start

If the pump is completely silent, check your switchboard first. If the breaker or safety switch for the pump has tripped, you can reset it once. If it trips again, leave it off. A breaker that keeps tripping is protecting you from an electrical fault, and finding that fault is a job for a licensed electrician. Energy Safe Victoria is clear that electrical work in your home must be carried out by a licensed electrician.

Don’t open the pump’s control box or the cover on the pressure switch to have a look. Both have live terminals inside, even when the pump isn’t running.

The Pump Runs but No Water Comes Through

A pump that hums along without delivering water is usually telling you something about the water supply rather than the electrics. The most common cause is that the water level in the bore has dropped below the pump, which happens more often in long dry spells when the aquifer isn’t being recharged. A blocked intake, a split pipe between the bore and the tank, or plain wear in an older pump can cause the same symptom.

Check whether every outlet is affected or just one line, and think back over the last few weeks. If the flow dropped off gradually before it stopped, that points towards the water level or wear. Our guide to what happens after the drilling rig leaves explains what falling pressure in a Victorian bore usually means.

Don’t leave a pump running when it isn’t moving water. Many pumps rely on the water flowing through them to stay cool, and running dry can damage them quickly. Switch it off at the isolator and get it checked.

Do You Need to Prime a Bore Pump?

Most Victorian water bores use submersible pumps that sit inside the bore casing, below the standing water level. Because they’re already surrounded by water, submersible pumps don’t need priming.

Priming applies to surface pumps, which sit above ground and draw water up through a suction line. If your surface pump keeps losing its prime, air is usually getting into the suction side or the water level has dropped too far for the pump to lift it. Follow the priming steps in your pump’s manual. If it keeps losing prime after that, the cause needs finding rather than repeated re-priming.

The Pump Keeps Cycling On and Off

A pressure switch turns your pump on when the pressure in the system falls and off again once it’s built back up. If the pump keeps kicking in when nobody’s using water, something is letting that pressure drop.

Start with leaks, because they’re the most common cause and the easiest to find. Turn off every tap and outlet you know about, then listen. If the pump still starts every few minutes, look for a running float valve on a trough, a leaking irrigation line, a dripping tap or a toilet that won’t stop filling.

If there’s no leak, the cause is more likely the pressure tank (many lose their air charge over time, which makes the pump cycle in short bursts) or the pressure switch itself. Both should be checked and adjusted by someone qualified, because the switch is wired to mains power. Rapid cycling also wears a pump out faster, so it’s worth sorting out sooner rather than later.

Sand, Discoloured Water or a Smell

These usually point to the bore rather than the pump. Sand or sediment coming through your taps or troughs usually means the bore’s screen or gravel pack isn’t filtering properly, although opening a tap too hard can also pull sediment in. Discoloured, cloudy or smelly water is another sign the bore needs a proper look.

Sand is also hard on pumps, so ignoring it tends to turn a bore problem into a pump problem as well. Sand, discolouration and odour changes need an inspection from a licensed driller, not just a pump service.

When to Call, and What to Have Ready

It’s time to call in help if:

  • the breaker trips again after one reset
  • the pump runs but won’t deliver water
  • the pump keeps cycling and you can’t find a leak
  • sand, sediment, discolouration or a smell appears in the water
  • the pump has stopped completely, or the bore hasn’t been checked in several years

We don’t offer emergency or same-day callouts, and a visit is usually about a week away depending on our schedule. So call as soon as you notice something’s off rather than waiting for the pump to stop altogether. If your stock rely on the bore, line up a backup water supply in the meantime.

When you call, it helps to know what the pump is doing (use the table above), when it started, whether it came on suddenly or gradually, and who drilled the bore. We can service and repair many bores we didn’t originally drill, depending on their age, construction and condition.

FAQs

Can I fix a bore pump myself?

You can safely check the breaker, look for leaks and note the symptoms. Anything beyond that, such as opening the control box, adjusting the pressure switch or pulling a submersible pump out of the bore, needs a licensed electrician or an experienced bore and pump technician.

Why does my bore pump keep turning on and off?

Usually because something is letting the system pressure drop, most often a leak. If you can’t find a leak, the pressure tank or pressure switch is the next likely cause.

Do you service bores you didn’t drill?

In many cases, yes. It depends on the bore’s age, construction and condition, so we assess each one individually.

Bore Pump Still Playing Up?

If you’ve done the safe checks and the problem’s still there, get in touch and tell us what the pump is doing. Our bore servicing and repairs team will work out whether it’s the pump, the bore or the water, and give you an honest view on whether to repair or replace.